Find Industrial MRO Parts Fast
Search millions of maintenance, repair and operations parts across global brands. Click a result to view details and request a quote.
Showing results for: tex
Search: tex
TRANSMITTER PRESSURE:INLINE GAUGE -14.7 TO 10000PSI 4 TO 20MA DIGITAL SIGNAL BASE OUTPUT 1/2-14 FNPT +/-0.075PCT 10.5 TO 42.4VDC LCD DISPLAY M20 X 1.5 BRACKET 2IN PIPE CSA AND ATEX EP ALUM HOUSING 316L SS ISOLATING DIAPH...
TRANSMITTER TEMPERATURE:DIN A HEAD MOUNT 4 TO 20MA HART DIGITAL OUTPUT SGL SENSOR INPUT LCD DISPLAY ALUM HOUSING -20 TO 300DEC C ATEX INTRINSIC SAFETY PT100-385 4 WIRE UNIVERSAL JUNCTION BOX HOUSING M20 X 1.5MM CABLE ENT...
TRANSMITTER DIFFERENTIAL PRESSURE:COPLANAR -248 TO 248BAR 4 TO 20MA DIGITAL HART OUTPUT ALTERNATE PROCESS CONNECTION 316L SS ISOLATING DIAPHRAGM GLASS FILLED PTFE O-RING SILICONE SENSOR FILL FLUID SS HOUSING F/ ROSEMOUNT...
TRANSMITTER PRESSURE:INLINE GAUGE 14.7 TO 800PSI 4 TO 20MA DIGITAL HART OUTPUT 1/2IN-14 FNPT M20 X 1.5MM CABLE ENTRY 2IN PIPE BRACKET/PANEL MOUNT ATEX INTRINSIC SAFETY & DUST ALLOY C276 DIAPHRAGM SS HOUSING SILICONE SENS...
TRANSMITTER TEMPERATURE:SINGLE POINT 4 TO 20MA HART DIGITAL OUTPUT SGL SENSOR INPUT LCD DISPLAY SS FIELD MOUNT HOUSING ATEX INTRINSIC SAFETY SS FIELD MOUNT DUAL-COMPARTMENT HOUSING M20 X 1.5 (CM20) CONDUIT ENTRY LCD DISP...
TRANSMITTER PRESSURE:SCALABLE COPLANAR GAUGE -14.2 TO 2000PSI FOUNDATION FIELDBUS PROTOCOL OUTPUT 10.5 TO 42.4VDC INPUT ULTRA 0.025PCT SPAN ACCURACY 9 TO 32VDC LCD DISPLAY M20 X 1.5 CABLE ENTRY ATEX INTRINSIC SAFETY ALUM...
TRANSMITTER DIFFERENTIAL PRESSURE:SCALABLE COPLANAR -300 TO 300PSI FOUNDATION FIELDBUS PROTOCOL OUTPUT 9 TO 32VDC 0.025PCT SPAN ACCURACY ALLOY 400 ISOLATING DIAPHRAGM ASSEMBLE TO ROSEMOUNT 305 INTEGRAL MANIFOLD ALUM PLAN...
TRANSMITTER PRESSURE:INLINE GAUGE -14.7 TO 30PSI FOUNDATION FIELDBUS PROTOCOL OUTPUT 9 TO 32VDC INPUT 1/2-14 FNPT LCD DISPLAY M20 X1.5 CABLE ENTRY ATEX INTRINSIC SAFETY AND DUST ALUM HOUSING 316L SS DIAPHRAGM 316L SS WET...
TRANSMITTER PRESSURE:INLINE GAUGE 14.7 TO 800PSI FOUNDATION FIELDBUS PROTOCOL OUTPUT 9 TO 32VDC INPUT 1/2IN-14 FNPT LCD DISPLAY M20X 1.5 CABLE ENTRY ATEX INTRINSIC SAFETY AND DUST ALUM HOUSING ALLOY C276 DIAPHRAGM ALLOY...
DETECTOR FIRE PROTECTION:SMOKE -20 TO 70DEG C 16 TO 28VDC MODEL MR601TEX
ALARM:MANUAL CALLPOINT 28VDC M20 ENTRY ATEX/CENELEC EXI YELLOW DUTY LABEL AND TAG LABEL REQUIRED 7 X 2.5MM2 W/ INLINE AND END OF LINE RESISTOR
ALARM:MANUAL CALLPOINT 28V ATEX/CENELEC-EXI M20 RED DUAL LABEL AND TAG LABEL REQUIRED SGL CHANGEOVER 7 X 2.5MM2 TERMINAL W/ INLINE AND END OF LINE RESISTOR
